PB980_Banner_Image

Introducing the Puritan Bennett™ 980 Ventilator: Engineered to help patients breathe more naturally

The new Puritan Bennett™ 980 ventilator helps enable patients to breathe more naturally through some of the most innovative breath delivery technology available.

Our simple, safe and smart design provides more natural ventilation that may help improve patient comfort.1

Simple

Our innovative user interface features a highly customizable display with intuitive screen navigation.

Safe

The newly designed Puritan Bennett™ 980 ventilator provides a unique ventilator assurance feature and an integrated expiratory filtration system.

Smart

Advanced synchrony tools help clinicians set the ventilator to adapt to their patients’ unique needs and help provide the appropriate level of support throughout the breath.

How To Buy

Image for Product Tour 980 Link

Take the Product Tour of the Puritan Bennett™ 980 Ventilator

Learn more about the new ventilator.

[ Start The Tour ]

Puritan Bennett™ 980 Ventilator Highlights

Image for Sedation Feature Callout

Explore Sedation Issues

Learn more about reducing sedation use in your facility.

[ Learn More ]

pb980-brochure-image

Adult ICU Brochure

Learn how the Puritan Bennett 980 ventilator can help support more natural breathing for patients in the ICU.

[ Download the Brochure ]

Image for PB 980 NICU Brochure

NICU Brochure

Learn more about neonatal ventilation with the Puritan Bennett 980 ventilator.

[ Download the Brochure ]

compared to conventional mechanical ventilation (VC, VC+, PC and PS)

1. Grasso S, Puntillo F, Mascia L, et al. Compensation for increase in respiratory workload during mechanical ventilation. Pressure-support versus proportional-assist ventilation. Am J Respir Crit Care Med. 2000;161(3 Pt 1):819-26.)

Back To Top

Key Features of the Puritan Bennett™ 980 Ventilator

PB980-key-features-image

Intuitive, highly configurable touch screen

Unique expiratory filtration system

Status display provides additional information about battery status, power source, peak pressure and other vital monitored information

Digital communication board for USB connections and HDMI output

DC compressor

Hot swappable batteries

Intuitive and Highly Configurable Touch Screen

  • Viewing graphics
    • Graphs may be scaled and enlarged to full screen to improve visibility.

    • Using the pause button, you can pause the screen and review the last 60 seconds of patient data.

  • Large-font screen
    • In situations where you may not be directly in front of the screen, or during teaching situations where there are several people in the room, the large-font screen can provide greater visibility to patient data.

  • Screen configurability
    • Several configuration options enable you to see as little or as much information as you need.
    • Patient data in the top banner may be configured to the patient need or to match your workflow document. Additional patient data can be accessed by scrolling right to left in the upper right corner. Patient data cells may be left blank to reduce the amount of visible patient data.

    • The touch screen also offers easy access to five graph and loop layout options.

Back to top

Safety Features

  • Unique ventilation assurance feature
    • In the event of certain system failures, the ventilator will continue to deliver ventilatory support as close to the preset settings as feasible. Ventilation assurance feature is unique to the Puritan Bennett 980 ventilator that may help improve safety for ventilated patients in the event of certain system failures.
  • Stand-by mode
    • Stand-by mode pauses ventilation when the patient is disconnected and preserves settings; auto-detects patient upon reconnection; and automatically resumes ventilation without the need to push additional buttons.

  • Status display
    • There is an additional screen located on the breath delivery unit (BDU) that provides a redundant check of ventilator operation

      PB 980 Status Display

  • Hot swappable batteries
    • The Puritan Bennett 980 ventilator houses up to two batteries without a compressor installed.
    • Batteries may be changed or swapped out without having to power down the ventilator and interrupt patient ventilation.
  • Expiratory filtration system
    • The unique expiratory filtration system of the Puritan Bennett ventilators helps provide a high level of safety from cross contamination for both patients and staff members.
    • Puritan Bennett filters have a rating of > 99.97%.

Back to top

Connectivity

  • Digital communication board
    • The digital communication board provides multiple USB ports for connections to external drives and an HDMI output port that can be used to project the touch screen externally.
  • Connecting to EMR system
    • The Puritan Bennett 980 ventilator has several options for connecting to external systems.

Back to top

Patient Monitoring

  • Proximal flow sensor
    • The proximal flow sensor measures flow, pressure and tidal volume right at the patient wye in neonate applications.

Back to top

Synchrony Tools

  • Advanced synchrony tools help clinicians set the ventilator to adapt to their patients' unique needs and help provide the appropriate level of support throughout the breath. Learn more about unique synchrony tools from Covidien for Puritan Bennett ventilators.
  • Puritan Bennett™ PAV™*+ Software

Back to top

How To Buy

Image for Product Tour 980 Link

Take the Product Tour of the Puritan Bennett™ 980 Ventilator

Learn more about the new ventilator.

[ Start The Tour ]

Sedation_website_image

Explore Sedation Issues

Learn more about reducing sedation use in your facility.

[ Learn More ]

Specifications

Puritan Bennett™ 980 Ventilator Settings
Predicted body weight (PBW) Neonatal: 0.3 kg to 7.0 kg (0.66 lb to 15 lb); Pediatric: 3.5 kg to 35 kg (7.7 lb to 77 lb); Adult: 25 kg to 150 kg (55 lb to 330 lb)
Modes Assist/Control (A/C), Synchronized Intermittent Mandatory Ventilation (SIMV), Spontaneous (SPONT), BiLevel 2.0 or Continuous Positive Airway Pressure (CPAP)
Software NeoMode 2.0, Leak Sync, BiLevel 2.0, Proportional Assist™* Ventilation Plus (PAV™*+)
Mandatory breath types Volume Control (VC), Pressure Control (PC) or Volume Control Plus (VC+)
Spontaneous breath types Pressure Support (PS), Volume Support (VS), Proportional Assist™* Ventilation Plus (PAV™*+) and Tube Compensation
Vent type Invasive or Noninvasive
Pressure support (PSUPP) 0 to 70 cmH2O
Rise time % 1% to 100%
Expiratory sensitivity (ESENS) 1% to 80% in PS and VS; 1 L/min to 10 L/min with PAV™*+
Tidal volume (VT) 25 to 2,500 mL, Neonatal: 2 mL to 315 mL
Respiratory rate (f) 1.0 to 100 1/min pediatric/adult, 1.0 to 150 1/min neonatal
Peak inspiratory flow (VMAX) 3 to 150 L/min for adult; 3 to 60 L/min for pediatric; 1 to 30 L/min for neonatal
Flow pattern Square or descending ramp
Plateau time (TPL) 0.0 to 2.0 seconds
Inspiratory pressure (PI) 5 to 90 cmH2O
Constant during rate change I:E ratio, TI, TE for PC or VC+; TH:TL ratio, TH, TL in BiLevel mode
Inspiratory time (TI) 0.2 to 8.0 seconds
I:E ratio ≤ 1:299 to 4:1; in BiLevel mode TH:TL range is 1:299 to 149:1
Expiratory time (TE) ≥ 0.2 seconds
Trigger type Pressure (PTRIG) or flow (VTRIG)
Pressure sensitivity (PSENS) 0.1 to 20 cmH2O
Flow sensitivity (VSENS) 0.1 to 10 L/min for neonatal; 0.2 to 20 L/min for pediatric/adult
O2% 21% to 100%
Apnea ventilation Apnea mandatory type—Volume Control (VC) or Pressure Control (PC)
Apnea flow pattern Square or descending ramp
Apnea peak inspiratory flow (VMAX) 1.0 L/min to 30 L/min for neonatal, 3.0 L/min to 60 L/min for pediatric, 3.0 L/min to 150 L/min for adult
Apnea tidal volume (VT) 3 mL to 15 mL for neonatal; ≥ 25 mL to 2500 mL for pediatric/adult
Apnea inspiratory pressure (PI) 5 cmH2O to 90-PEEP cmH2O
Apnea inspiratory time (TI) 0.2 to 8.0 seconds
Apnea interval (TA) 10 to 60 seconds or OFF in CPAP
Apnea respiratory rate (f) 2.0 to 40 1/min
Apnea O2% 21% to 100%
Apnea expiratory time (TE) ≥ 0.2 seconds
Disconnect sensitivity (DSENS) 20% to 95% or OFF when Leak Sync disabled; when Leak Sync is enabled: 1 to 15 L/min for neonatal, 1 to 40 L/min for pediatric, 1 to 65 L/min for adult
Humidification type Heat-moisture exchanger (HME), nonheated expiratory tube or heated expiratory tube
Humidifier volume 100 to 1,000 mL
Patient circuit type Neonatal, pediatric or adult

*Proportional Assist and PAV are registered trademarks of The University of Manitoba, Canada. Used under license.

How To Buy

PB980-tech-brochure-OUS-image

Explore Specifications (U.S. Only)

Download the technical specifications brochure.

[ Learn More ]

PB980-nicu-tech-brochure-OUS-image

Explore Neonatal Specifications (U.S. Only)

Download the neonatal technical specifications brochure.

[ Learn More ]

Training

A suite of education tools provide product education for clinicians learning to use the Puritan Bennett™ 980 ventilator. Tools are also provided for hospital educators to help conduct facility training programs for the Puritan Bennett 980 ventilator.

Puritan Bennett™ 980 Ventilator Pre-Reading Booklet

The pre-reading booklet may serve as a pre-training document to help prepare for a live training session or as a resource following training.

Learn more

Puritan Bennett™ 980 Ventilator Touch Screen Handout

The touch screen handout serves as a guide for trainees to follow along with the live training session. The handout features a select number of important screen shots that call out certain features and benefits and can be used to take notes during a training session.

Learn more

Puritan Bennett™ 980 Ventilator Quick Reference Guides

Quick reference guides are concise, one-page documents that explain how to set up and manage certain features on the ventilator.

Learn more

Puritan Bennett™ 980 Ventilator Pocket Guide [US ONLY]

The Puritan Bennett 980 ventilator pocket guide is a quick reference guide to ventilator features that are most commonly used during daily patient care.

Learn more

Puritan Bennett™ 980 Ventilator Training Implementation Guide

The Puritan Bennett 980 training implementation guide helps training facilitators prepare for and conduct training for the Puritan Bennett 980 ventilator. The implementation guide includes training best practices, lesson plans and training planning tools.

Learn more

Puritan Bennett™ 980 Ventilator Training Implementation Checklists

The Puritan Bennett 980 training implementation checklists help training facilitators prepare for and conduct training for the Puritan Bennett 980 ventilator. The implementation checklists are tailored to three clinical audiences (nurses, RTs, physicians).

Learn More

Puritan Bennett™ 980 Ventilator Education Presentations

The product education presentations provide training on a variety of topics related to the Puritan Bennett 980 ventilator. They may be used during the initial training or as a resource following training. The presentations are organized into small individual chapters to facilitate ease of learning.

Learn more

Puritan Bennett™ 980 Ventilator Clinical Application Lesson Plan

The clinical application lesson plan provides training on the software and modes available on the Puritan Bennett 980 ventilator. It may be used during the initial training or as a resource following training. The presentations are organized into small individual chapters to facilitate ease of learning.

Learn more

Puritan Bennett™ 980 Ventilator Practice Exercises

The practice exercises are example scenarios that can be used during training sessions to help practice the information learned.

Learn more

Puritan Bennett™ 980 Ventilator Training Evaluation

The training evaluation card is an example of collecting feedback on a training session to facilitate future improvement in training sessions and to identify areas of additional education that may be needed.

Learn more

How To Buy

PB980_Pocket_Guide_Image

Download Pocket Guide

The Puritan Bennett™ 980 ventilator pocket guide serves as a quick reference to the most commonly used ventilator features during daily care of ventilated patients.

[ Learn more ]

PB980_Quick_Cards_Image

Download Quick Reference Guides

Puritan Bennett™ 980 ventilator quick reference guides are concise, one-page documents that explain how to set up and manage certain features on the ventilator.

[ Learn more ]

How To Buy

Resources

Puritan Bennett™ 980 Ventilator Series Product Tour Video

Learn more about the Puritan Bennett 980 ventilator series.

Watch Video

Puritan Bennett™ 980 Ventilator Series – Adult ICU Brochure

Learn more about ventilating patients in adult ICUs with the Puritan Bennett 980 ventilator series.

Download Now

Puritan Bennett™ 980 Ventilator Series – NICU Brochure

Learn more about neonatal ventilation with the Puritan Bennett 980 ventilator series.

Download Now

Puritan Bennett™ 980 Ventilator Specifications

Explore the Puritan Bennett 980 ventilator specifications.

Download Now

How To Buy

Image for Product Tour 980 Link

Take the Product Tour of the Puritan Bennett™ 980 Ventilator

Learn more about the new ventilator.

[ Start The Tour ]

PB980-nicu-tech-brochure-OUS-image

Explore Neonatal Specifications (U.S. Only)

Download the neonatal technical specifications brochure.

[ Learn More ]